Time adjustment and control
Home > to set re-locking time
How to set re-locking time in the Prima solenoid bolt
Back

Push button No. 1 top button

This function allows to adjust the re-locking time after the door is closed.

Time adjustment between 0-5 seconds from re-locking after door opening. When the door is closed the timing starts.

Checking

Pushing slowly with a screw-driver on the button for just one second, the LED starts flashing.

Any flash represents 1 second programmed. i.e. 2 flashes mean that the door will re-lock 2 sec after the leaf of the door is closed.

Programming

Push the button for 4 sec until the LED is lit on. Keep pushing the button. The LED will lit off and will start flashing.

Any flash represents one second. Leave the button (do not push any longer). The LED will advise you about the setting received flashing; any flash is one second.

 

Push button No. 2 middle button

This function allows to adjust the re-locking time in case the door is not moved after opening command.

Time adjustment between 0-60 seconds from re-locking after door opening. When the door is closed the timing starts.

Checking

Pushing slowly with a screw-driver on the button for just one second, the LED starts flashing.

Any flash represents 5 seconds programmed. i.e. 2 flashes mean that the door will re-lock 10 sec after the opening command is given.

Programming

Push the button for 4 sec until the LED is lit on. Keep pushing the button. The LED will lit off and will start flashing.

Any flash represents 5 seconds. Leave the button (do not push any longer). The LED will advise you about the setting received flashing; any flash is 5 seconds.

 

Push button No. 3 bottom button - Only available in 246-248 Prima series

This function allows to get an alarm in case the door remains open after the time set is over.

Time adjustment between 0-120 seconds from door opening. When the door is open the timing starts.

The alarm outlet must be connected to the BLU wire (12V-) and to the power supply (12V+)

Checking

Pushing slowly with a screw-driver on the button for just one second, the LED starts flashing.

Any flash represents 10 seconds programmed. i.e. 2 flashes mean that the alarm will start after 20 sec after the door is open.

Programming

Push the button for 4 sec until the LED is lit on. Keep pushing the button. The LED will lit off and will start flashing.

Any flash represents 10 seconds. Leave the button (do not push any longer). The LED will advise you about the setting received flashing; any flash is 10 seconds.

 

 