Home > Electronic control unit for interlocking |
Electronic control unit for interlocking system
Related products: Electronic card for managing one door (or more interlocking doors) for use with electric strikes series 346/348, safety electromagnets series 13100, 13700, solenoid bolts series 206, 208, 216, 218, 219 |
Code 54610
Electronic unit for single door. It is used to temporize the opening or closing of an electric lock |
This unit is used to temporize the opening or closing of the electric locks and strikes. Plastic box dimensions : 240x150x48 mm. Operating voltage : 12/24 Vac/dc Power consumption: 60 mA in stand by. Microprocessor electronic. Arranged for interlock connection between 2 or more doors. - Input for opening contact - Input for block - Input for Emergency and Alarm reset - Input for bolt position - Input for door's leaf position - Output with relay C./N.O./N.C. for connection with indicator lamps - Output with relay C./N.O./N.C. for alarm prolonged door opening, breakdown, emergency, simultaneous opening of 2 or more doors if connected in interlock configuration. Push buttons for monitoring and adjustment of reclosing times from 0-5 sec. to approach of door and from 0-60 sec. if the door is not opened.
|
|
|
This sophisticated door interlock controller allows 2, 3 or 4 doors to be interlocked to restrict or control entry to and from areas that need to be secured against two or more doors being open simultaneously
|
Code 54710
Electronic unit for 2 doors. It is used to connect two doors in interlocking
|
This unit is used to make an interlocking system between 2 doors. The doors must be equipped with electric locks. Plastic box dimensions : 240x150x48 mm. Operating voltage : 12/24 Vac/dc Power consumption: 60 mA in stand by. Microprocessor electronic. Arranged for interlock connection between 2 or more doors. - Input for opening contact - Input for block - Input for Emergency and Alarm reset - Input for bolt position - Input for door's leaf position - Output with relay C./N.O./N.C. for connection with indicator lamps - Output with relay C./N.O./N.C. for alarm prolonged door opening, breakdown, emergency, simultaneous opening of 2 or more doors if connected in interlock configuration. Push buttons for monitoring and adjustment of reclosing times from 0-5 sec. to approach of door and from 0-60 sec. if the door is not opened. USE : Electronic card for managing one door (or more interlocking doors) for use with electric strikes series 346/348, safety electromagnets series 13100, 13700, solenoid bolts series 206,208,216,218,219
|
|
|