Controller for electromagnetically retained fire doors
English version Back
Home > Single zone controller

 

Related products :

 

SINGLE-ZONE CONTROLLER FOR ELECTROMAGNETICALLY RETAINED FIRE DOORS

Once a fire has been detected, this controller allows the release of electromagnetic door retainers, thereby closing the fire doors, and an alarm signal that is able to be reset using a manual control

 

Tested in accordance with regulation BS EN 54 part 2 and part 4

 

Regulation EN 54 refers to the Construction Products Directive 89/106/EEC

Regulation EN 54-2 concerns control and indicating equipment for fire detection and fire alarm systems

Regulation EN 54-4 concerns power supply equipment for fire detection and fire alarm systems

 

 

 

 

 

 

 

 

 

 

 

Opera Srl - 52002

 

52002 - Fire Control unit

 

 

 

 

 

 

52002 - Single zone fire controller

The 52002 single-zone controller was designed and manufactured in accordance with regulation EN 54 part 2 and part 4, and is particularly suited for fire prevention installations of small dimensions. 

It can control up to 4 electromagnetic door retainers and 5 fire and smoke detectors

1.   Technical specifications:


      Power:

  1. Principal, from mains 230 V AC 50-60Hz
  2. Auxiliary, provided by 2 batteries 12 V DC 1.2Ah ( provided separately on request )

      Operational zones: Single zone

      User interface:

Main panel with LEDs indicating the operational state of the exchange, with the following displays:

  1. Fire alarm indicator light
  2. Mains power presence/absence indicator light
  3. Auxiliary (battery) power presence/absence indicator light
  4. Exchange fault indicator light
  5. Sensor line fault indicator light
  6. Remote alarm activation button line fault indicator light
  7. Manual ‘exchange out of order’ status indicator light
  8. Sounder out of order's status indicator light
  9. Door retainers power's status indicator lamp
  10. System out of order indicator lamp

 

            Inputs (on terminal):

  1. Heat and smoke sensor line
  2. Remote alarm activation button line
  3. Remote manual electromagnetic release button line  
  4. Acoustic alarm (buzzer + output relay) suppressing/reactivating button

            Outputs (on terminal):

  1. Magnets line (up to four – max 300 mA absorption)
  2. Output 12V DC – 1.5 A max per connection with remote alarm signalling lamp
  3. 1 output for connection with an external acoustic alarm ( additional siren ) functioning in parallel with the internal alarm of the exchange
  4. 1 output on the COM/NA/NC contacts of the relay (2 A) for external signalling of the ‘out of order’/fault status of the exchange

Other functions:

  1. Signalling of the presence/absence of mains power
  2. Signalling of the presence/absence of the auxiliary (battery) power
  3. Check on the quality of the battery
  4. Suppressing of the alarm signal from the exchange
  5. Reactivation of the alarm signal following a new alarm signal from any one of the detection devices
  6. Possibility of manually placing the exchange out of order for maintenance purposes
  7. Identification and signalling (visual and acoustic) of the efficiency of the sensor and remote fire alarm activation button lines

 

 

 

 

Top

 

 

Opera Srl - Art. 05203

 

 

05203 - Smoke and heat detectors

• EN54 approved

• Low operational voltage : 10.5V to 33V

• Aesthetically discreet

• Superior performance and reliability

• Designed for rapid installation

• Integrated alarm led

• Remote led connection

• Wiring polarity independent

• Compatible with standard mounting base and with relay base

 

 

 

Opera Srl - Art. 05203

 

05204 - Heat rate of rise detectors

• EN54 approved

• Low operational voltage : 10.5V to 33V

• Aesthetically discreet

• Superior performance and reliability

• Designed for rapid installation

• Integrated alarm led

• Remote led connection

• Wiring polarity independent

• Compatible with standard mounting base and with relay base


 
Top

05207 - Fire alarm sounder

Flexible alarm sounder for Fire and security applications complete with volume and dil switch to provide 28 or 32 tones

Ip rating: base IP54 - sounder IP65

Rated voltage : 9-30 Vdc

 

 

 

 
 

 

Opera Srl - Art. 05206

05206 - Test spray for smoke detectors

With the test spray 05206 you can check whether or not your optical smoke detector reacts to visible smoke particles.

Contet 150ml for approx 1500 applications

 

 