Connection diagram for electric handle
Opera
Home > Electric handle > Connection diagram for electric handle 40801
Print
Back
 

 

 

 

This version has an internal timer to set re-locking time

The power supply used in this drawing is the part no. 05320

 

Download installation and wiring manual ( Pdf 294 Kb )

 

40801 - Opera

40801
The electric handle is disabled (in neutral) with the red LED lit.
Press and release the opening button and the LED switches to green, the buzzer is enabled, it switches on and the handle allows the door to be opened.
This state lasts for the time set on the timer (from 5 to 60 seconds), or until the first time the handle is used.

To open again, the opening button needs to be pressed again. The use of a lead cover is recommended - do not use tappet contacts

SETTING THE TIMER

The electric handle is equipped with an internal timing system that makes it possible to keep the handle enabled for a time decided at the user's discretion.

Setting the timer to 0 seconds

  1. Connect the programming button (not included) to the blue wire and the signals ground (GND) to the green wire.
  2. Connect the electric handle to the power supply (gray and white wires).
  3. The green LED lights up on the panel. Keep pressing the programming button until the LED changes to orange and a prolonged audible signal sounds. Release the programming button immediately. The LED will switch on for about one second and emit an audible signal to confirm the programming. In this mode, the electric handle will remain enabled for the duration of the electrical pulse only.

Setting the timer to 5-60 seconds

    • Connect the programming button (not included) to the blue wire and the signals ground (GND) to the green wire.
    • Connect the electric handle to the power supply (gray and white wires).
    • The green LED lights up on the panel. Keep pressing the programming button until the LED changes to orange and a prolonged audible signal sounds. Keep the button pressed and the LED will flash in time with pairs of audible signals, each lasting 5 seconds. Release the programming button when the timing gets to the desired setting. The LED confirms the setting by flashing and emitting audible signals according to the selected timing. In this mode, the electric handle will remain enabled either for the set time or until it is operated.

     

     

 
Top